Integration for Tivoli
Appendix B: HP SNMP events 73
Tivoli types TEC class Description TEC priority
cpqSeCpuStatus:failed
IM_1006_4 — Fatal
cpqSeCpuStatus:disabled
IM_1006_5 — Warning
CpqSeCpuPowerPodstatusChang
e (1007)
— This event occurs when the CPU Power Pod
status changes.
—
cpqSeCpuPowerpodStatus:NotFai
led
IM_1007_1 — Harmless
cpqSeCpuPowerpodStatus:Failed
IM_1007_2 — Fatal
cpqSeUSBStorageDeviceAttached
IM_1008 This event occurs when a USB device is
inserted.
Harmless
cpqSeUSBStorageDeviceRemoved
IM_1009 This event occurs when a USB device is
removed.
Harmless
Systems information (CPQSINFO.MIB)
Tivoli types TEC class Description TEC priority
cpqSiHoodRemoved (2001)
IM_2001 This event occurs when hood status has
been set to removed.
Critical
cpqSiMonitorConditionOK (2002)
IM_2002 This event occurs when the Fault reporting
features have returned to within their
normal operating range for the monitor.
Harmless
cpqSiMonitorConditionDegraded
(2003)
IM_2003 This event occurs when the monitor's
condition is degraded because the internal
temperature is exceeding normal
operating limits.
Warning
cpqSiMonitorConditionFailed
(2004)
IM_2004 This event occurs when the monitor's
condition has been set to Failed because
an operational feature is exceeding normal
operating limits.
Critical
cpqSiCorrMemErrStatusDegraded
(2005
IM_2005 This event occurs when the Correctable
memory error count has exceeded the
threshold for the memory module.
Warning
cpqSiCorrMemErrStatusOk
(2006)
IM_2006 This event occurs when the Correctable
memory error count is now below the
threshold for the memory module.
Harmless
cpqSiMemConfigChange (2007)
IM_2007 This event occurs when a memory
configuration change has occurred.
Harmless
cpqSiHotPlugSlotBoardRemoved
(2008)
IM_2008 This event occurs when a Hot Plug Slot
Board has been removed from the
specified chassis and slot.
Warning