Integration for Tivoli
Appendix B: HP SNMP events 71
Tivoli types TEC class Description TEC priority
cpqCrEMUFanFailureTrap (16)
IM_16 This event occurs when one of the cooling
fans in the primary enclosure has failed.
Fatal
cpqCrEMUFanInformationTrap
(17)
IM_17 This event occurs when the cooling fan in
the primary enclosure has recovered.
Harmless
cpqCrEMUPowerSupplyFailureTra
p (18)
IM_18 This event occurs when one of the power
supplies in the primary enclosure has
failed.
Fatal
cpqCrEMUPowerSupplyInformatio
nTrap (19)
IM_19 This event occurs when the power supply in
the primary enclosure has recovered.
Harmless
cpqCrExpCabFanFailureTrap (20)
IM_20 This event occurs when one of the cooling
fans in the expansion cabinet has failed.
Fatal
cpqCrExpCabFanInformationTrap
(21)
IM_21 This event occurs when the cooling fan in
the expansion cabinet has returned to a
normal state.
Harmless
cpqCrExpCabPowerSupplyFailure
Trap (22)
IM_22 This event occurs when one of the power
supplies in the expansion cabinet has
failed.
Fatal
cpqCrEMUTemperatureWarningT
rap (23)
IM_23 This event occurs when the temperature in
the primary enclosure has triggered a
warning condition detected by the
controller.
Warning
cpqCrEMUTemperatureCriticalTra
p (24)
IM_24 This event occurs when the temperature in
the primary enclosure has triggered a
critical condition detected by the controller.
Critical
cpqCrEMUTemperatureInformatio
nTrap (25)
IM_25 This event occurs when the temperature in
the primary enclosure has returned to
normal.
Harmless
cpqCrExpCabTemperatureWarni
ngTrap (26)
IM_26 This event occurs when the temperature in
the expansion cabinet has triggered a
warning condition detected by the
controller.
Warning
cpqCrExpCabTemperatureCritical
Trap (27)
IM_27 This event occurs when the temperature in
the expansion cabinet has triggered a
critical condition detected by the controller.
Critical
cpqCrExpCabTemperatureInform
ationTrap (28)
IM_28 This event occurs when the temperature in
the expansion cabinet has returned to
normal.
Harmless
cpqCrExpCabPowerSupplyInform
ationTrap (29)
IM_29 This event occurs when the power supply in
the expansion cabinet has recovered.
Harmless
cpqCrPhyDiskInformationTrap
(30)
IM_30 This event occurs when a disk drive has
recovered.
Harmless
cpqCrPhyDiskFailureTrap (31)
IM_31 This event occurs when a disk drive has
failed.
Fatal
cpqCrPhyDiskReconstructTrap
(32)
IM_32
This event occurs when a disk member of a
logical drive has begun the reconstruction
process and will be available for use when
reconstruction is complete.
Warning