Integration for Tivoli
Installing the HP Insight Integration with the TEC 41
3.
Open the existing tecad_snmp.cds file for editing. By default, the file for non-TME adapters is
located in the /tecsnmp/etc directory. For the ACF adapter, this file is located in the $LCFDIR
/TME/TEC/adapters/etc directory, where $LCFDIR represents the Endpoint directory
environment.
4. If a previous version of the Compaq Insight Manager Integration for Tivoli Enterprise is installed, then
delete all existing entries that begin with CIM_.
5. If a previous version of the Insight Integration for TEC is installed, then delete all existing entries that
begin with IM_.
6. Append all entries from the ins_evt.cds file located in the hpq/TEC directory to the original
tecad_snmp.cds file.
7. Save the updated tecad_snmp.cds file.
8. Open the tecad_snmp.oid file for editing.
9. If a previous version of the Compaq Insight Manager Insight Integration for Tivoli or Insight Integration
for TEC was installed, then delete all existing entries that begin with cpq.
10. Add all entries from the ins_evt.oid file located in the hpq/TEC directory to the original
tecad_snmp.oid file.
11. Be sure that the OID entries are in numerical order.
12. Save the updated tecad_snmp.oid file.
13. Restart the TECSNMPAdapter service.
Manually copying existing SNMP Adapter files to another
Managed Node
When there are multiple systems in a TME that require a configured SNMP Adapter, instead of running the
HP configuration task on each target Managed Node or Endpoint, the associated .cds and .oid files can be
configured once and copied to each target system.
The following process presumes that the Configure SNMP Adapter task supplied with the Insight Integration
has already been run on the TMR server and that the updated tecad_snmp.cds and tecad_snmp.oid files
have already been created.
1. Be sure that the target Managed Node or Endpoint is installed with a Tivoli non-TME adapter. By
default, the non-TME adapter installation creates the following directories:
o C:\Tecsnmp\etc
o C:\Tecsnmp\bin
NOTE: A UNIX® configuration uses the /etc/Tivoli/tecad reference.
2. On the target Managed Node, stop the TECSNMPAdapter service.
3. Make backup copies of the current tecad_snmp.cds and tecad_snmp.oid files. This precaution
preserves the working configuration, and the adapter can be easily restored, if required.
4. Replace the existing tecad_snmp.cds and tecad_snmp.oid files in the C:\Tecsnmp\etc directory with
the files already created using the Configure SNMP Adapter task provided with the Insight Integration.
5. Restart the TECSNMPAdapter service to complete the process and initiate the newly updated event
classes and definitions on the Managed Node.