Integration for Tivoli
Installing the HP Insight Integration with the TEC 40
13.
Click the Event Groups tab, and use the Assign Groups button to select the event groups and roles
associated with the console (in this example, HP Insight Events group is used).
14. Click the Operators tab, and assign current operators from the list of available operators.
15. Finish configuring the remaining tabs based on your specific organization requirements, and then click
OK to save the console.
Manually configuring the HP Insight Integration for
Tivoli
The HP Insight Integration for Tivoli was developed for easy installation using predefined scripts and tasks. To
provide maximum flexibility with existing Tivoli environments and to meet individual customer needs, some
elements of Insight Integration can be configured manually.
The following sections describe how to manually configure the following elements of the TEC application to
receive and display HP SNMP and Fibre Channel Management events:
• Tivoli SNMP Adapter
• Tivoli Event Server
Manually updating the Tivoli SNMP Adapter on a managed node
The following process can be used to manually update an existing SNMP Adapter to receive the HP ProLiant
event definitions and classes provided with HP Insight Integration for Tivoli 5.1. The event definitions support
Insight Management Agents up to version 8.70. To update the adapter:
1. Shut down the TECSNMPAdapter service.
2. Copy the existing tecad_snmp.cds and tecad_snmp.oid files, and then save them in a separate
location. This precaution enables you to restore the original configuration, if needed.