The following third-party SNMP traps provide support for some HP hardware platforms and subsystems:
• Fibre Channel Management (FCMGMT-MIB) supporting HP Virtual Connect
Each defined event has been assigned severity and correlation conditions, which can be customized to suit
individual requirements.
Configuring a Tivoli non-TME SNMP Adapter
To configure a Tivoli non-TME SNMP Adapter:
1. Confirm that the TME is configured and operating correctly before attempting to configure the SNMP
Adapter (TMR server, Tivoli Gateways, and the TEC application).
2. Confirm that a Tivoli non-TME Adapter is installed on at least one Managed Node or Endpoint within
the TME.
3. Confirm that the adapter class definition file provided with the Insight Integration, ins_evt.cds, has been
copied to the /etc directory of the system hosting the Tivoli non-TME adapter.
4. From the HP Insight Integration for Tivoli window on the Tivoli Desktop, double-click Insight
Administration Tasks, and then right-click the Configure SNMP Adapter icon.
5. Select Run on selected subscribers. The Execute Task window appears.
NOTE: The following example is based on a default Tivoli installation. To make changes to an
existing configuration, select the Modify job option.
6. Use the arrow buttons to select the target systems that contain the Tivoli non-TME Adapter from the list
of available options. Be sure that the selected targets are included in the selection windows on the left.
NOTE: The TME requires only a single non-TME SNMP Adapter for use with the TEC. Configure
the SNMP services on HP Managed Nodes and Endpoints to send traps to the Tivoli SNMP
Adapter.