Integration for Tivoli
Appendix B: HP SNMP events 232
Tivoli types TEC class Description TEC priority
cpqSwccKzpccSubsystemEventTr
ap (3)
This event occurs when some event has
happened to a KZPCC controller.
cpqSwccKzpccEventSeverity:info
rmational
IM_Kzpcc_
3_1
— Harmless
cpqSwccKzpccEventSeverity:war
ning
IM_Kzpcc_
3_2
— Critical
cpqSwccKzpccEventSeverity:erro
r
IM_Kzpcc_
3_3
— Fatal
Blade Type-2 traps (BT2TRAPS.MIB)
Tivoli types TEC class Description TEC priority
bt2SwPrimaryPowerSupplyFailur
e (1)
IM_BT2_1 This event occurs when the primary power
supply failed.
Fatal
bt2SwDefGwUp(2)
IM_BT2_2
This event occurs when the default gateway
is alive.
Harmless
bt2SwDefGwDown(3)
IM_BT2_3
This event occurs when the default gateway
is down.
Harmless
bt2SwDefGwInService(4)
IM_BT2_4
This event occurs when the default gateway
is up and in service.
Harmless
bt2SwDefGwNotInService(5)
IM_BT2_5 This event occu
rs when the default gateway
is alive but not in service.
Harmless
bt2SwVrrpNewMaster (16)
IM_BT2_16 This event occurs when the sending agent
has transitioned to 'Master' state.
Harmless
bt2SwVrrpNewBackup(17)
IM_BT2_17 This event occurs when the sending agent
has transitioned to 'Backup' state.
Harmless
bt2SwVrrpAuthFailure(18)
IM_BT2_18 This event occurs when there is an
authentication failure.
Critical
bt2SwLoginFailure(19)
IM_BT2_19 This event occurs when there is a login
failure.
Critical
bt2SwTempExceedThreshold
(22)
IM_BT2_22 This event occurs when the switch
temperature has exceeded maximum safety
limits.
Fatal
bt2SwRackLocationChange(26)
IM_BT2_26 This event occurs when the rack location has
been changed.
Harmless
bt2SwApplyComplete(27)
IM_BT2_27
This event occurs when a new configuration
has been applied.
Harmless
bt2SwSaveComplete(28)
IM_BT2_28 This event occurs when the new
configuration has been saved.
Harmless
bt2SwFwDownloadSucess(29)
IM_BT2_29 This event occurs when the firmware has
been downloaded.
Harmless
bt2SwFwDownloadFailure(30)
IM_BT2_30 This event occurs when the firmware
downloaded failed.
Warning
bt2SwTempReturnThreshold(31)
IM_BT2_31 This event occurs when the switch
temperature has returned below maximum
safety limits.
Harmless
bt2SwFanFailure(32)
IM_BT2_32 This event occurs when a fan failure has
been detected.
Critical
bt2SwFanFailureFixed(33)
IM_BT2_33 This event occurs when the fan failure has
been fixed.
Harmless
bt2SwUfdfoLtMFailure(34)
IM_BT2_34 This event occurs when an LtM link is down.
Critical