Integration for Tivoli

Installing the HP Insight Integration with the TEC 21
13.
Populate the Clients to Install On list with the designated target systems. Use the left and right arrow
buttons to move machine names from Available Clients to Clients to Install On. Install the Insight
Integration in sequence to the following systems:
o TMR server
o TEC server
o Associated gateways
14. Click Install. The Product Install window appears, which logs the installation as it runs, initially listing the
tasks that take place during the installation. To begin the installation, click Continue Install, or to cancel
the installation, click Cancel.
15. After the installation is complete, click Close.
NOTE: The approximate time to install the HP Insight Integration for Tivoli is 10 to 15 minutes,
depending on the overall TME configuration.
Installing from the command line
The HP Insight Integration for Tivoli 5.1 can be installed from the command line using the hptiv_install.sh
script. This script is present in the hpq/Plus/Utils directory and installs the Plus Module Support (Link Binaries)
and the HP Insight Integration for Tivoli into the TMR servers. The following procedure describes installing
Insight Integration from a command line:
1. Run the script from a command line in a Tivoli managed environment, for example, sh
hptiv_install.sh.
2. When prompted, provide full path to the hpq directory where Insight Integration for Tivoli files are
extracted, for example, /Tivoli/IM/hpq on UNIX® platform and C:/Progra~1/Tivoli/IM/hpq on
Windows® platform.
3. The installation process installs Plus Module Support (Link Binaries) into the TMR servers and managed
nodes. HP Insight Integration for Tivoli cannot be installed without Link binaries already installed in the
TMR server or managed node. Select y to proceed with the installation of Link binaries, or select n to
skip installation if Link binaries already exist.
4. After Link Binaries are installed, HP Insight Integration for Tivoli is installed into the TMR servers. Select
y to proceed with installation, or select n to exit without installation.
By default, the script installs the Link Binaries and Insight Integration for Tivoli files on all the available
Managed Nodes. The script file can be customized for installation on specific Managed Nodes.
To install a different revision of the HP Insight Integration for Tivoli, uninstall the current revision of using steps,
and then install the new revision of the HP Insight Integration for Tivoli following the procedures described in
this section.