Integration for Tivoli

Appendix B: HP SNMP events 140
Tivoli types TEC class Description TEC priority
sCellEventTrap-0c-08(136
03080)
IM_13603080 This event occurs when a
Full Copy is terminated
prior to completion: A
remote copy error
occurred due to an
inaccessible Destination
Virtual Disk. The Full Copy
will continue when the
Destination Virtual Disk is
restored.
Fatal
sCellEventTrap-0c-09(136
03081)
IM_13603081 This event occurs when a
Data Replication Log is
reset due to insufficient
Disk Group capacity. The
Data Replication
Destination is marked for
a Full Copy.
Minor
sCellEventTrap-0c-0a(136
03082)
IM_13603082 This event occurs when a
Data Replication Log is
reset due to a Data
Replication Group
failover.
Harmless
sCellEventTrap-0c-0c(136
03084)
IM_13603084 This event occurs when a
Destination Data
Replication Group
successfully completes a
Merge.
Harmless
sCellEventTrap-0c-0f(136
03087)
IM_13603087 This event occurs when a
Data Replication Group is
no longer in a Failsafe
Locked state.
Harmless
sCellEventTrap-0c-10(136
03088)
IM_13603088 This event occurs when a
Destination Data
Replication Group is
marked for a Full Copy.
Harmless
sCellEventTrap-0c-11(136
03089)
IM_13603089 This event occurs when the
Data Replication Group is
transitioning from a Data
Replication Source role to
a Data Replication
Destination role.
Harmless
sCellEventTrap-0c-12(136
03090)
IM_13603090 This event occurs when the
Data Replication Group is
transitioning from a Data
Replication Destination
role to a Data Replication
Source role.
Harmless
sCellEventTrap-0c-16(136
03094)
IM_13603094 This event occurs when an
HSV300 controller sends
a time report message to
this HSV300 controller.
Harmless