Integration for Tivoli
Appendix B: HP SNMP events 138
Tivoli types TEC class Description TEC priority
sCellEventTrap-09-d8(136
02520)
IM_13602520 This event occurs when a
Redundant Storage Set
has two members on the
same Fibre Channel
device enclosure causing
a Disk Group to lose its
Single Point of Failure
Robust Configuration.
Fatal
sCellEventTrap-09-d9(136
02521)
IM_13602521 This event occurs when a
Disk Group attains a
Single Point of Failure
Robust Configuration.
Harmless
sCellEventTrap-09-da(136
02522)
IM_13602522 This event occurs when an
HSV300 controller's
blower 1 is running at
normal speed.
Harmless
sCellEventTrap-09-db(136
02523)
IM_13602523
This event occurs when an
HSV300 controller's
blower 2 is running at
normal speed
Harmless
sCellEventTrap-09-dd(136
02525)
IM_13602525 This event occurs when an
HSV300 controller
receives a maintenance
invoke call from the user.
Harmless
sCellEventTrap-09-de(136
02526)
IM_13602526 This event occurs when an
internal logical disk
transitions to the
INVALIDATED state.
Fatal
sCellEventTrap-0b-00(136
02816)
IM_13602816 This event occurs when an
HSV300 controller begins
a resynchronization
operation. This is a restart
of the HSV300 controller
with little or no impact on
host system connectivity.
Harmless
sCellEventTrap-0b-01(136
02817)
IM_13602817 This event occurs when a
migrate method drive
codeload stalls due to
insufficient space in the
Disk Group.
Minor
sCellEventTrap-0b-04(136
02820)
IM_13602820 This event occurs when a
Fibre Channel physical
disk drive firmware
codeload begins.
Harmless
sCellEventTrap-0b-05(136
02821)
IM_13602821 This event occurs when a
Fibre Channel physical
disk drive firmware
codeload finishes.
Harmless