Integration for Tivoli
Appendix B: HP SNMP events 136
Tivoli types TEC class Description TEC priority
sCellEventTrap-09-7d(136
02429
IM_13602429 This event occurs when the
flags of a physical disk
drive change because of a
maintenance mode
change.
Harmless
sCellEventTrap-09-7e(136
02430)
IM_13602430 This event occurs when the
defer_copy attribute of a
Data Replication Group
changes.
Harmless
sCellEventTrap-09-7f(136
02431)
IM_13602431 This event occurs when a
Data Replication Group is
suspended due to link
down.
Harmless
sCellEventTrap-09-80(13
602432)
IM_13602432 This event occurs when a
Data Replication Group is
suspended due to site
failover.
Harmless
sCellEventTrap-09-81(13
602433)
IM_13602433 This event occurs when a
Data Replication Group is
suspended due to defer
copy.
Harmless
sCellEventTrap-09-82(13
602434)
IM_13602434 This event occurs when the
split brain allow attribute
of a Data Replication
Group changes.
Harmless
sCellEventTrap-09-c8(136
02504)
IM_13602504 This event occurs when an
internal logical disk
transitions to the DATA
LOST state.
Fatal
sCellEventTrap-09-c9(136
02505)
IM_13602505 This event occurs when a
Disk Group transitions to
an INOPERATIVE state..
Fatal
sCellEventTrap-09-ca(136
02506)
IM_13602506 This event occurs when an
internal logical disk
transitions to the FAILED
state.
Fatal
sCellEventTrap-09-cb(136
02507)
IM_13602507 This event occurs when an
internal logical disk
transitions to the
SNAPSHOT
OVERCOMMIT state.
Fatal
sCellEventTrap-09-cc(136
02508)
IM_13602508 This event occurs when an
internal logical disk
transitions to the DEVICE
DATA LOST state.
Fatal
sCellEventTrap-09-cd(136
02509)
IM_13602509 This event occurs when a
Fibre Channel port
transitions to the FAILED
state.
Fatal
sCellEventTrap-09-ce(136
02510)
IM_13602510 This event occurs when a
Disk Group transitions to
an INOPERATIVE
MARKED state.
Harmless