Integration for Tivoli

Appendix B: HP SNMP events 127
Tivoli types TEC class Description TEC priority
sCellEventTrap-06-65(13
601637)
IM_13601637 This event occurs when an
HSV300 controller detects
a change in the Enclosure
B-side link module
temperature sensor.
Harmless
sCellEventTrap-06-66(13
601638)
IM_13601638 This event occurs when an
HSV300 controller detects
a change in the Enclosure
midplane condition.
Harmless
sCellEventTrap-06-67(13
601639)
IM_13601639 This event occurs when an
HSV300 controller detects
a change in the Enclosure
midplane temperature
sensor condition.
Harmless
sCellEventTrap-06-68(13
601640)
IM_13601640 This event occurs when an
HSV300 controller detects
only one port of an
Enclosure device.
Fatal
sCellEventTrap-06-69(13
601641)
IM_13601641 This event occurs when a
previously reported
Enclosure device with only
one port is corrected and
redundancy is restored.
Harmless
sCellEventTrap-07-00(13
601792)
IM_13601792 This event occurs when
Allocation of a Virtual Disk
stalls due to insufficient
space in the Disk Group
caused by the failure or
pulling of a physical disk
drive.
Minor
sCellEventTrap-07-01(13
601793)
IM_13601793 This event occurs when
Expansion of a Virtual
Disk stalls due to
insufficient space in the
Disk Group caused by the
failure or pulling of a
physical disk drive.
Minor
sCellEventTrap-07-02(13
601794)
IM_13601794 This event occurs when the
leveling of capacity in a
Disk Group starts.
Harmless
sCellEventTrap-07-03(13
601795)
IM_13601795 This event occurs when the
leveling of capacity in a
Disk Group is finished.
Harmless
sCellEventTrap-07-04(13
601796)
IM_13601796 This event occurs when a
member management
operation starts due to the
appearance or
disappearance of a
physical disk drive.
Harmless
sCellEventTrap-07-05(13
601797)
IM_13601797 This event occurs when a
member management
operation finishes.
Harmless