Integration for Tivoli
Appendix B: HP SNMP events 124
Tivoli types TEC class Description TEC priority
sCellEventTrap-06-40(13
601600)
IM_13601600 This event occurs when the
physical disk drive has
properties that might or
might not be compatible
with this release of
Enterprise Virtual Array
firmware. The drive is
prevented from being
used until the Approved
Drive Firmware table is
updated to allow it.
Fatal
sCellEventTrap-06-41(13
601601)
IM_13601601 This event occurs when
devices are listed in loop
order using their ALPAs.
Harmless
sCellEventTrap-06-42(13
601602)
IM_13601602 This event occurs when a
user command is sent to a
physical disk drive.
Harmless
sCellEventTrap-06-4b(136
01611)
IM_13601611 This event occurs when the
HSV300 controller is
instructed to Enable or
Disable Loop Recovery
Operations
Harmless
sCellEventTrap-06-4c(136
01612)
IM_13601612 This event occurs when the
arbitrated loop physical
address of the physical
disk drive is contained in
the al_pa field.
Harmless
sCellEventTrap-06-4d(136
01613)
IM_13601613 This event occurs when the
HSV300 controller is
finished attempting to
codeload all Drive
Enclosure Environmental
Monitoring Unit hardware
requiring updates, and
completes staggered
codeload, if necessary.
Harmless
sCellEventTrap-06-4e(136
01614)
IM_13601614 This event occurs when a
physical disk drive reports
a non-zero RSP_CODE in
response to an I/O.
Harmless
sCellEventTrap-06-4f(136
01615)
IM_13601615 This event occurs when an
Enclosure Link Module
begins updating its code
Do not power down the
Enclosure until the code
update is completed.
Harmless
sCellEventTrap-06-50(13
601616)
IM_13601616 This event occurs when an
Enclosure Link Module
completes updating its
code. It is now safe to
power down the
Enclosure.
Harmless