Integration for Tivoli
Appendix B: HP SNMP events 123
Tivoli types TEC class Description TEC priority
sCellEventTrap-06-31(13
601585)
IM_13601585 This event occurs when a
previously reported Fibre
Channel device enclosure
with only one port is
corrected and redundancy
is restored.
Harmless
sCellEventTrap-06-32(13
601586)
IM_13601586 This event occurs when an
HSV300 controller detects
only one port of all Fibre
Channel devices on a
loop.
Fatal
sCellEventTrap-06-33(13
601587)
IM_13601587 This event occurs when a
previously reported Fibre
Channel loop with only
one port is corrected and
redundancy is restored.
Harmless
sCellEventTrap-06-34(13
601588)
IM_13601588 This event occurs when an
HSV300 controller
enables a device port,
and that device port is not
disabled during boot
diagnostics.
Harmless
sCellEventTrap-06-36(13
601590)
IM_13601590 This event occurs when an
unsupported Fibre
Channel physical disk
drive firmware revision is
detected by the physical
disk drive firmware load
process.
Fatal
sCellEventTrap-06-37(13
601591)
IM_13601591 This event occurs when a
Fibre Channel physical
disk drive firmware
revision is detected by the
physical disk drive
firmware load process that
is later than the latest
known supported revision.
Harmless
sCellEventTrap-06-38(13
601592)
IM_13601592 This event occurs when a
Fibre Channel physical
disk drive firmware
revision is detected by the
physical disk drive
firmware load process that
has a newer supported
revision available.
Harmless