Integration for Tivoli

Appendix B: HP SNMP events 107
Tivoli types TEC class Description TEC priority
cpqRackServerBladePOSTComple
ted(22068)
IM_22068 This event occurs when the server blade
system BIOS POST has completed.
Harmless
cpqRackServerBladePoweredOn(
22069)
IM_22069 This event occurs when the server blade is
powered on.
Harmless
cpqRackServerBladePoweredOff(
22070)
IM_22070 This event occurs when the server blade is
powered off.
Harmless
cpqRackInformationalEAETrap(22
071)
IM_22071 This event occurs when EAE Informational
.trap occurs
Harmless
cpqRackMinorEAETrap(22072)
IM_22072 This event occurs when EAE Minor trap
occurs.
Minor
cpqRackMajorEAETrap(22073)
IM_22073 This event occurs when EAE Major trap
occurs.
Critical
cpqRackCriticalEAETrap(22074)
IM_22074 This event occurs when EAE Critical trap
occurs.
Fatal
cpqRackPowerMinorEAETrap(22
075)
IM_22075 This event occurs when FlexFabric Cmdr
Power Subsystem Minor trap occurs.
Minor
cpqRackPowerMajorEAETrap(22
076)
IM_22076 This event occurs when FlexFabric Cmdr
Power Subsystem Major trap occurs.
Critical
cpqRackPowerCriticalEAETrap(22
077)
IM_22077 This event occurs when FlexFabric Cmdr
Power Subsystem Critical trap occurs.
Fatal
Console management controller (CPQCMC.MIB)
Tivoli types TEC class Description TEC priority
cpqCmcalarmTemp1 (153001)
This event occurs when the temperature at
rack sensor 1 is outside the specified
threshold.
CpqCmcStatusTemp1: normal
IM_15300
1_2
Harmless
CpqCmcStatusTemp1:warning
IM_15300
1_3
Warning
CpqCmcStatusTemp1:overMax
IM_15300
1_4
Critical
CpqCmcStatusTemp1:underMin
IM_15300
1_5
Critical
CpqCmcStatusTemp1:noSensor
IM_15300
1_6
Critical
CpqCmcStatusTemp1:error
IM_15300
1_7
Fatal
cpqCmcalarmTemp2 (153002)
This event occurs when the temperature at
rack sensor 2 is outside the specified
threshold.
CpqCmcStatusTemp2:normal
IM_15300
2_2
Harmless
CpqCmcStatusTemp2:warning
IM_15300
2_3
Warning
CpqCmcStatusTemp2:overMax
IM_15300
2_4
Critical
CpqCmcStatusTemp2:underMin
IM_15300
2_5
Critical