Integration for Tivoli

Appendix B: HP SNMP events 100
Tivoli types TEC class Description TEC priority
cpqRPMTrapUPSInputVoltageNo
rmal (20003)
IM_20003 This event occurs when a UPS device is
reporting input voltage is normal.
Harmless
cpqRPMTrapUPSOutputVoltageB
elowMin (20011)
IM_20011 This event occurs when a UPS device is
reporting output voltage is below minimum
threshold.
Warning
cpqRPMTrapUPSOutputVoltageA
boveMax (20012)
IM_20012 This event occurs when a UPS device is
reporting output voltage above maximum
threshold.
Warning
cpqRPMTrapUPSOutputOverloa
d (20014)
IM_20014 This event occurs when a UPS device is
reporting an overload condition.
Critical
cpqRPMTrapUPSOutputOverloa
dCleared (20015)
IM_20015 This event occurs when a UPS device is
reporting an overload condition has been
cleared.
Harmless
cpqRPMTrapUPSBatteryDepleted
(20022)
IM_20022 This event occurs when a UPS device is a
depleted battery.
Critical
cpqRPMTrapUPSBatteryLevelNor
mal (20023)
IM_20023 This event occurs when a UPS device is
reporting battery level is normal.
Harmless
cpqRPMTrapUPSOnBypass
(20032)
IM_20032 This event occurs when a UPS device is
being bypassed.
Warning
cpqRPMTrapUPSTemperatureLo
w (20101)
IM_20101 This event occurs when a UPS device is
reporting temperature below minimum
threshold.
Critical
cpqRPMTrapUPSTemperatureHig
h (20102)
IM_20102 This event occurs when a UPS device is
reporting temperature above maximum
threshold.
Critical
cpqRPMTrapUPSTemperatureNo
rmal (20103)
IM_20103 This event occurs when a UPS device is
reporting temperature is normal.
Harmless
cpqRPMTrapUPSInternalFailure
(20111)
IM_20111 This event occurs when a UPS device is
reporting a general UPS failure.
Fatal
cpqRPMTrapUPSInternalFailureC
leared (20112)
IM_20112 This event occurs when a UPS device is
reporting a general UPS failure has been
cleared.
Harmless
cpqRPMTrapUPSBatteryFailure
(20121)
IM_20121 This event occurs when a UPS device is
reporting a battery failure.
Fatal
cpqRPMTrapUPSBatteryFailureCl
eared (20122)
IM_20122 This event occurs when a UPS device is
reporting a battery failure has been cleared.
Harmless
cpqRPMTrapUPSDiagnosticTestF
ailed (20131)
IM_20131 This event occurs when a UPS device is
reporting a diagnostic test failed.
Critical
cpqRPMTrapUPSDiagnosticTestS
ucceeded (20132)
IM_20132 This event occurs when a UPS device is
reporting a diagnostic test succeeded.
Harmless
cpqRPMTrapUPSInputUnderOver
Freq (20141)
IM_20141 This event occurs when measured input
frequency is outside of either the upper or
lower frequency limit specification for
normal operation.
Harmless
cpqRPMTrapUPSInputUnderOver
FreqCleared (20142)
IM_20142 This event occurs when a UPS device is
reporting measured input frequency is
normal.
Harmless
cppqRPMtrapUPSStartedOnBatte
ry (20151)
IM_20151 This event occurs when a UPS device has
been started while on battery power. AC
input power is not present.
Harmless