HP Insight Control Server Provisioning 7.3 Update 1 Build Plans Reference Guide
59
--method='METHOD' - This parameter is not required as the target server should power off before the boot
ever begins, but it can be specified without consequences. Possible values:
- auto - it will behave as embedded or network, depending on the target server
- embedded - supported only if the IloService is enabled on the target server and this is a HP ProLiant
Gen8. The following service OSs are possible: linux, linux64, or winpe64.
- network - configures PXE network booting into the selected Service OS if the IloService is enabled on
the target server it will also set the one time boot option to NETWORK. Specifying an ogfs PXE-
option as the Service OS is supported.
--wait <time> - Specify a new wait time. Default is 45 seconds.
Custom Attributes: None
Remap Windows Drives
Remaps the volumes to new drive letters, starting with "C". Network drives are not remapped since those drive letters
are explicitly assigned. The "X" drive is reserved for WinPE and is not remapped either.
Type: Python
Optional Parameter:
--reservedDriveLetters="letter1 letter2 ... letterN" A space separated list of drive letters that are not to be
assigned during the remapping.
Custom Attributes: None
Report Windows SPP Installation Results
This script works with the "Install Windows SPP In Background" script. It reports the results of the SPP installation, by
collecting the HP SUM return code and log data from a file left behind by the Install Windows SPP In Background step.
Type: Python
Optional Parameter:
--fail_on_warning - Causes the build plan step to fail if the HP SUM return code is -3, which means that there
were some components that could not be installed. By default a -3 is recorded as a success.
Custom Attributes: None
Reset System Configuration
Resets the target server's BIOS system configuration to factory default settings using the rbsureset utility.
As part of the reset, the date and time on the target server is reset.
NOTE: The system settings are not actually reset until the next server power cycle. Always follow this step with the
Reboot to Apply BIOS Changes and Power Off step which will perform this power cycle.
Type: Unix
Parameters: None
Custom Attributes: None
Run Windows 2008 R2 x64 Setup
Run Windows 2008 x64 Setup
Run Windows 2012 x64 Setup
Starts the appropriate Windows operating system installation by call the setup.exe specified in the script parameter.
Type: Windows .BAT
Required Parameters: