HP Insight Control Server Provisioning 7.3 Update 1 Build Plans Reference Guide
34
Custom Attributes: None
ProLiant HW - Boot Local Disk
Boots a target server into production via its local disk.
NOTE: The build plan expects an agent to be running on the target when the build plan completes or the build plan will
fail, even if the target boots successfully.
Requirements: HP ProLiant server with iLO
Custom Attributes: None
ProLiant HW - Clear UEFI Boot Menu
Deletes all custom boot options from the UEFI boot menu. These are boot options that were added to the UEFI boot
menu by previously installed operating systems or manually by the user. This build plan removes all the custom boot
options, even the one for the currently installed operating system. This build plan should only be run if planning to
install a new operating system, otherwise the currently installed operating system may fail to boot.
Requirement:
HP ProLiant server with iLO that support UEFI
Custom Attributes: None
ProLiant HW - Erase Server
Resets a server and disks to factory defaults.
IMPORTANT: Running this build plan causes data loss.
This build plan deletes the partition table on the server's disks, clears the Smart Array configuration on any attached
Smart Array controllers, and resets the system BIOS settings to default values. The server's state is changed to
unmanaged. Note that when the BIOS is reset, the BIOS date/time becomes incorrect.
This build plan may be modified to meet your needs. For example, if your server has no Smart Array, you might need to
remove the steps that reset it.
Requirements: HP ProLiant server with iLO
Custom Attributes: None
ProLiant HW - Fibre Channel HBA Configure Boot Device
Configures the boot device for an Emulex HBA, Emulex CNA, or Qlogic HBA using custom attributes.
To support Emulex or QLogic HBA, or Emulex CNA scripted configuration, this build plan configures the boot device using
the settings specified in the HBA_Config custom attribute. The configuration of the boot device is necessary in order to
allow the server to boot from SAN. For further information on how this build plan is used, refer to the How Do I … ?
section of the IC server provisioning online help.
Requirements: HP ProLiant server with iLO and an Emulex HBA, Emulex CNA, or QLogic HBA but not Emulex and QLogic
at the same time.
Required Custom Attributes: HBA_Config
ProLiant HW - Fibre Channel HBA Display Configuration
Displays the Emulex or QLogic HBA, or Emulex CNA configuration settings to the job log.
The Emulex or QLogic HBA, or Emulex CNA configuration is displayed to provide information about any HBAs found on
the target server, such as the HBA WWPN, link status, enable BIOS setting, selectable boot setting, primary boot port
name, and LUN.
Requirements: HP ProLiant server with iLO and an Emulex HBA, Emulex CNA, or QLogic HBA but not Emulex and QLogic
at the same time.