HP Insight Control Server Provisioning 7.2 Online Help

Table Of Contents
12.20 Build Plan fails and target server is at Intelligent Provisioning screen
12.20.1 Symptom
A Linux, Windows, or ESXi Build Plan fails at the Wait for HP SA Agent step following the Reboot
step, and the target server shows the Intelligent Provisioning screen.
12.20.2 Resolution
This is caused by an intermittent timing problem. Run the Build Plan again.
12.21 Unable to install to a multi-disk system
12.21.1 Symptom
Each operating system detects hard drives in a different order, so on multi-disk systems there is no
guarantee which disk will be selected for installation. HP-provided RHEL and SLES Build Plans will
install to all detected hard drives by default. Existing data is wiped and a new partition layout is
created. The HP-provided ESXi Build Plan installs only to the first detected drive.
12.21.2 Resolution
Disable all but the intended drive on RBSU or explicitly state in the answer file which drive to install
to.
12.22 ESXi installation repeats
12.22.1 Symptom
In general, this happens when trying to install ESXi on multi-disk systems. The default Insight Control
server provisioning ESXi answer file instructs installation to occur on the first available disk.
Depending on how ESXi detects hard drives in the system, the first available disk might not be the
intended installation drive.
12.22.2 Resolution
Disable all disks except the installation disk on System RBSU or explicitly state in the ESXi answer
file the disk number to install to.
12.23 ESXi installation fails with gateway message
12.23.1 Symptom
Your ESXi installation with static addressing fails with a console message about failing to specify
a gateway.
12.23.2 Resolution
A gateway is required for OS deployment of ESXi 5.x. Specify a gateway on the Run OS Build
Plan page by checking Configure static network information and entering your gateway in the
Server Network Configuration area.
12.24 ESXi installation has nameserver warning
12.24.1 Symptom
Your ESXi installation with static addressing shows a warning on the console that a nameserver
was not specified.
12.20 Build Plan fails and target server is at Intelligent Provisioning screen 107