HP Insight Control 7.3 Update 1 Release Notes

Issues and suggested actions
Issues and limitations of this release are listed below, organized by HP Insight Control product or
functional area. The following categories are used. If a product area has no limitations or issues,
that category will not appear.
Limitations Limitations of the implemented functions and features of this release
Major issues Issues that may significantly affect functionality and usability in this release
Minor issues Issues that may be noticeable but do not have a significant impact on
functionality or usability
Known issue
Abnormal behavior for patch updates on multiple windows
A CMS can have different login sessions. When a user logs into multiple window login sessions
of a CMS, the user can run 7.3.1 installer in multiple window login sessions at a time, which may
or may not lead to the installation failure.
Suggested action
User must not run the installer in multiple window login sessions at a time to install 7.3.1 version.
HP Insight Control power management
Limitations
Limitations in IC Power due to lack of IPv6 support in iPDU
The following limitations are experienced in IC Power due to a lack of IPv6 support in iPDU for
customers who are connected in IPv6:
1. Intelligent Power discovery feature are not supported when iPDU is configured with iPV6
address only.
a. iPDU, its load segments and outlets are not visible. Power information and reports will
not be available for these power delivery devices.
b. Enabling and disabling power of an iPDU outlet.
c. Powering on/off the UID LED of an iPDU.
Suggested action
The following Power Management features will be available for user even if the iPDU is discovered
with IPv6 address, but the devices (mentioned below) need to be discovered manually if they are
connected to iPDU:
1. Visualization of the layout of racks, systems/devices in a rack.
2. Viewing power information of racks, systems/devices, C-Class enclosures.
3. Viewing reports/export reports of systems (servers/enclosures)
4. Set the power caps, change power regulator mode, refresh power/thermal data of systems
(servers / enclosures).
NOTE: All features are supported, with the following exceptions:
Power operations for ProLiant 100 are not supported.
Association of chassis node for SL series servers is not supported.
Graceful shutdown of Local VMs on IPv6 only hosts is not support.
Intelligent Power discovery features are not supported when iPDU is configured with IPv6
address only.
Issues and suggested actions 9