HP Insight Control 7.3 Update 1 Release Notes
IPv4 address is not displayed in inventory for ProLiant SL 250s Gen8 and ProLiant DL 360p Gen8
For ProLiant SL 250s Gen8 and ProLiant DL 360p Gen8, the IPv4 address is not displayed in
inventory.
Counters are not displaying for some PCI devices
For some PCI devices, performance counters are not displayed.
For some NIC adapters (for example, NC7782 and NC7170) all network ports are shown as
disabled or not configured in Online Analysis
Network ports can sometimes appear as disabled or not configured in online analysis for some
network adapters when they are configured in a server running Microsoft Hyper-V technology in
Windows or configured as a bridge in Linux.
Details of NIC teaming type and the involved ports are not displayed
Network adapters can be configured with different NIC teaming types to handle fail over. Also,
the IP Address will be configured on the Teamed NIC. Performance management does not display
the configured NIC teaming type, involved ports, or details in the inventory tab of the online analysis
page.
HP Insight Control performance management Managed VM Host server shows critical/unknown
icon in PF column after upgrading to new version of Insight Control
The VM Host server shows a critical/unknown icon under the PF column after upgrading to a newer
version of Insight Control, though it is re-registered and managed in Insight Control with virtual
machine after upgrade.
Suggested action
Perform the following steps:
1. Select the VM Host Server.
2. Run the “Identify systems” task in the Systems Insight Manager page.
NIC subsystem’s major or minor performance state (icon) is not reflected against the server or in
the PF column
When network components are stressed on the server, the Network Subsystem/NIC Adapter/NIC
Port components show minor or major state icons on the Online Analysis page. The consolidated
status, however, is not propagated to the Server Model status in Online Analysis or to the PF
(Performance State) icon in the Systems Insight Manager All Systems page.
Status does not change in Server Configuration Tree when you click on Previous/Next bottleneck
buttons in the Offline Analysis page
System subsystem components status and counter values are logged to the database for playback.
When you click on the Previous and Next buttons in a bottleneck condition, the Offline Analysis
page shows the data when the system was in a Minor or a Major State. The status icon and Analysis
explanation message the display correct information in the status tab with values listed on Counter
table; however, the normal status icon is displayed in the Server Configuration tree for the same
component.
Monitoring Administration page hangs after monitoring of the servers is started for the first time
Occasionally, the Monitoring Administration page hangs after monitoring of the servers is started
for the first time.
Suggested action
Restart HP Systems Insight Manager service.
28 Insight Control release notes