HP Insight Control 7.3 Update 1 Release Notes

Minor issues
Immediate Power data collection is not happening for racks and datacenter
Suggested action
For the unmanaged node to receive power data information, perform one of the following steps:
Calculate power history using the Reports Power Management Calculate Power History
menu option.
Click Refresh Data from the Display Power/Thermal data page to refresh the data for the
unmanaged node.
The web browser crashes while creating/editing a datacenter or rack
The web browser crashes while creating/editing a datacenter or rack. The crash information dialog
in Mozilla Firefox (about:crashes) may contain the following signature:
Caused by a plugin: Shockwave Flash (npswf32.dll)
Suggested action
Download and install the supported version of Adobe Flash player from http://get.adobe.com/
flashplayer.
Unable to shut down the hosts and guests in either a forced or graceful manner
VMware ESXi versions do not support SSH capability. A manual shutdown of the guests or hosts
will be required.
Suggested action
The hosts and guests can be powered on and off until HP more fully integrates power management
with VMware vCenter.
Inconsistent system details displayed when multiple browser instances opened sharing the same
user session
If you have multiple browser windows open to view different systems and these browser instances
share the same browser session, inconsistent system details data can be displayed inside some of
the browser instances.
Suggested action
Refresh the browser window that displays inconsistent system details. Start and sign in to HP Systems
Insight Manager using separate browser session:
For Microsoft Internet Explorer 8 (IE8), click File->New Session to start the new browser session.
For Mozilla Firefox, start multiple browser sessions using separate profiles. For example,
firefox.exe -no-remote -P profile_name.
Unable to display graphs and reports when the time difference between the CMS and Onboard
Administrator is more than 24 hours
HP Insight Control power management cannot display power/utilization/temperature graphs if
the time difference between the CMS and managed node is more than 24 hours, although data
collection status reports as successful. Power data is stored based on the managed node's time.
Suggested action
If the date and time on the CMS and managed nodes are inconsistent with their respective time
zones, then change the date and time to be consistent with their respective time zones.