HP Insight Control 7.3 Release Notes

Status does not change in Server Configuration Tree when you click on Previous/Next bottleneck
buttons in the Offline Analysis page
System subsystem components status and counter values are logged to the database for playback.
When you click on the Previous and Next buttons in a bottleneck condition, the Offline Analysis
page shows the data when the system was in a Minor or a Major State. The status icon and Analysis
explanation message the display correct information in the status tab with values listed on Counter
table; however, the normal status icon is displayed in the Server Configuration tree for the same
component.
Monitoring Administration page hangs after monitoring of the servers is started for the first time
Occasionally, the Monitoring Administration page hangs after monitoring of the servers is started
for the first time.
Suggested action
Restart HP Systems Insight Manager service.
HP ProLiant ML 350p Gen8 and ProLiant DL360p Gen8 Linux node Storage subsystem values
display “0” value for status counters in Online Analysis
HP ProLiant ML 350p Gen8 and ProLiant DL360p Gen8 Linux node displays values for the array
controllers status counters, but for the storage subsystem it displays "0" values for status counters
in online analysis.
Insight Managed System Setup Wizard
Limitations
Privilege elevation configuration that requires a password by the privilege elevation tool is not
supported
The Insight Managed System Setup Wizard supports privilege elevation only on a CMS that has
privilege elevation configured so that no password is required by the privilege elevation tool (such
as su and sudo). If you attempt to configure features when privilege elevation is turned on and this
requires a password, you may see failures in the wizard's execution output.
Suggested action
If a feature fails to configure correctly because of privilege elevation password requirements,
configure the feature outside of the managed system setup wizard.
To turn off the requirement for a password, use the HP SIM OptionsSecurityPrivilege Elevation
menu, and uncheck the check box labeled A password is required for this privilege elevation
tool”. Note that systems managed by the CMS must be reconfigured to reflect this configuration
change.
HP Integrated Lights-Out 3 (iLO 3) support
HP Integrated Lights-Out 3 (iLO 3) is supported in the current release of Insight Managed System
Setup Wizard. However, iLO 3 for ProLiant requires a minimum of firmware version 1.05.
Suggested action
Update iLO 3 ProLiant firmware to version 1.05 or newer.
The Insight Managed System Setup Wizard does not configure HP Integrity rx2620
In this release, using the Insight Managed System Setup Wizard to configure an HP Integrity rx2620
server is not supported.
Suggested action
Manually configure HP Integrity rx2620 servers.