HP Insight Control 7.3 Release Notes
Unable to shut down the hosts and guests in either a forced or graceful manner
VMware ESXi versions do not support SSH capability. A manual shutdown of the guests or hosts
will be required.
Suggested action
The hosts and guests can be powered on and off until HP more fully integrates power management
with VMware vCenter.
Inconsistent system details displayed when multiple browser instances opened sharing the same
user session
If you have multiple browser windows open to view different systems and these browser instances
share the same browser session, inconsistent system details data can be displayed inside some of
the browser instances.
Suggested action
Refresh the browser window that displays inconsistent system details. Start and sign in to HP Systems
Insight Manager using separate browser session:
• For Microsoft Internet Explorer 8 (IE8), click File->New Session to start the new browser session.
• For Mozilla Firefox, start multiple browser sessions using separate profiles. For example,
firefox.exe -no-remote -P profile_name.
Unable to display graphs and reports when the time difference between the CMS and Onboard
Administrator is more than 24 hours
HP Insight Control power management cannot display power/utilization/temperature graphs if
the time difference between the CMS and managed node is more than 24 hours, although data
collection status reports as successful. Power data is stored based on the managed node's time.
Suggested action
If the date and time on the CMS and managed nodes are inconsistent with their respective time
zones, then change the date and time to be consistent with their respective time zones.
HP Systems Insight Manager may not recognize the installed HP Insight Control power management
that followed immediately after an uninstallation of power management
When uninstalling HP Insight Control power management from HP-UX, HP Systems Insight Manager
will be restarted. If power management is installed immediately after it is uninstalled and before
Systems Insight Manager has fully restarted, power management will be installed successfully but
Systems Insight Manager may not recognize that power management is installed.
Suggested action
Use mxstatus to verify that Systems Insight Manager has fully restarted before attempting to
install power management. Use the mxstop and mxstart options to install the tools waiting to
be installed.
Crystal Reports: Racks in datacenter views show wrong color in Japanese
The DataCenter View page on these reports shows each rack in the datacenter in the column and
row it occupies by color, which represents the maximum recorded temperature for equipment in
that rack. That maximum temperature value is also displayed in the view.
When you run the reports in Japanese, the colors do not reflect the temperature; instead, they are
random colors. However, the temperature still shows the correct value in the Japanese reports.
Suggested action
Run the report in English or ignore the color of the racks and look only at the temperature value
displayed in the racks.
Issues and suggested actions 11