HP Intelligent Management Center Extended API User Guide

Query Single-Index Single-Interface Performance Summary Data
Query single-index single-interface performance summary data with certain criteria.
Interface URI
/perf/summaryData/interface
Access Method
HTTP
GET
Parameters
Query parameters
Index ID. Integer type. Required. No default value. For the valid values, see Query Performance
Indexes.
taskId
Device ID. Integer type. Required. No default value. For the valid values, see Query Device
Information.
devId
Start time. Long integer type. Optional. The value is the seconds counted from 00:00 on January 1,
1970 to the specified time.
beginTime
End time. Long integer type. Optional. The value is the seconds counted from 00:00 on January 1,
1970 to the specified time.
endTime
Instance index. Integer type. Required. No default value.objIndex
Data granularity. Integer type. Optional. No default value. Valid values include 0 (automatically
calculated data), 1 (original data), 2 (hourly data), and 3 (daily data).
dataGranularity
Returned Result
Status codes
200 (OK): Success.
Message header
HTTP/1.1 200 OK
Message body
<perfSummaryData>
<taskId>1</taskId>
<taskName>Interface Receiving Rate(bits/s)</taskName>
<devId>1</devId>
<instId>504</instId>
<objIndex>1</objIndex>
<objIndexDesc>[interface:InLoopBack0]</objIndexDesc>
<averageValue>0.0</averageValue>
<maximumValue>0.0</maximumValue>
<minimumValue>0.0</minimumValue>
<currentValue>0.0</currentValue>
<summaryValue>0.0</summaryValue>
</perfSummaryData>
336 Network Performance Management