HP Intelligent Management Center Extended API User Guide

Shut Down an Interface
Shut down an interface on a device based on device ID.
Interface URI
/plat/res/device/{deviceId}/interface/{ifIndex}/down
Access Method
HTTP
PUT
Parameters
Path parameter
Device ID.deviceId
Long integer type. Required. No default value.
Interface index.ifIndex
Long integer type. Required. No default value.
Returned Result
Status codes
204 (No Content): Success.
404 (Not Found): No data is found with the ID.
409 (Conflict): Failure. See Error Codes.
Message header
HTTP/1.1 204 No Content
...
Example
Shut down the interface with the index 2 and device ID 2.
Request
PUT http://imc_host:8080/imcrs/plat/res/device/2/interface/2/down
accept: application/xml
...
Response
HTTP/1.1 204 No Content
Shut Down an Interface 137