Ignite-UX version C.7.13.240 contains the following new features:
The B.11.31 install kernels have been updated. The VxVM-Tools bundle was updated to the 5.0.1
revision to support the new default layout for VxVM.
The following manual page entries are either added or updated:
auto_adm(1M)
ignite(1M)
ignite-client(1M)
ignite-config(1M)
ignite-ui(1M)
ignite-version(1M)
instl_adm(4)
make_net_recovery(1M)
save_config(1M)
Fixes for the following Change Requests:
QXCR1001048367. After update-ux, Ignite-UX now reconfigures the required libraries
as it should.
QXCR1001085082. The list_expander code was modified to include inactive LVM 2.2
volumes in its output.
QXCR1001086950. Selection and unselection of the post_config_script in itool now
works as expected.
QXCR1001087891. Loading of scsimgr now goes through as expected when vi is loaded
to edit the configuration or the environment file during installation.
QXCR1001102946. save_config can now handle any number of disks in a VxVM disk
group.
QXCR1001108276. When make_*_recovery commands are run in preview mode and
then resumed, the manifest file is created in the correct directory.
QXCR1001111254. list_expander doesn't walk through the autofs mount points anymore,
thus preventing them from getting mounted every time.
QXCR1001111586. make_*_recovery will exit with an appropriate message in the
presence of Cluster-wide Device Special File (cDSF). make_*_recovery does not support
the creation of an archive with volume groups configured using cDSF as input.
QXCR1001119119. make_net_recovery can now unmount the mounted client directory
after creating the network archive when the client has more than 30 LANs.
QXCR1001120228. The 11.31 install kernel was updated with VxVM 5.0.1 patch
PHKL_42115 to enable recognition of SAS based disk drives on rx2800 models.
QXCR1001121908. itool now accepts legacy hardware path even if it is longer than the
width of its text box in the 'More Info' window.
QXCR1001124612. The autoboot status of a client is now gathered along with primary
hardware path information with a single invocation of the setboot command. This will aid
in not overwhelming the Onboard Administrator when multiple installs are going on
simultaneously with virtual partitions on Superdome 2.
QXCR1001154804. Ignite-UX now supports and detects Oracle ASM configured disks during
the installation alongwith the LVM and VxVM configured disks on the system.
QXCR1001126779. When the configuration file is hand-edited and has no disk defined in
the root volume group, users will be allowed to correct that in the itool window.