Ignite-UX release notes HP-UX 11iv1, HP-UX 11iv2 and HP-UX 11iv3 (5900-2307, April 2012)

make_sys_image(1M)
manage_index(1M)
save_config(1M)
instl_adm(4)
ignite(5)
Fixes for the following Change Requests:
QXCR1000853553. Optical drives are no longer flagged as bad disks when empty.
QXCR1000879894. An issue where free physical extents exist on fully allocated 11.31 LVM
systems after cold install has been resolved.
QXCR1000881477. Ignite-UX will now hide all paths to disks specified in
_hp_hide_other_disks setting or via _hp_hide_boot_disk.
QXCR1000898153. In order to avoid problems with swapinfo reporting incorrect data on
B.11.31 when swapon -s has been used prior to creating a recovery image, and when the
swap configuration is modified interactively via itool, the/pri_swap_node KRS data will be
removed during an install. It will be recreated normally when the system boots.
QXCR1000913194. On systems with an MSA70 enclosure attached, Ignite-UX will now
correctly restore the legacy hardware paths for disks presented on the system.
QXCR1000922461. Installs of client images where Compartments have been enabled will
now succeed.
QXCR1000930199. Ignite-UX recovery has been improved to handle multi-byte utf8 characters
without errors.
QXCR1000933234. Log files for make_sys_image will now show up in the correct location
as given by the -d option.
QXCR1000939426. Ignite-UX will now recover escsi_ctlr instance numbers correctly
from network recovery images made with Ignite-UX version C.7.7 or earlier.
QXCR1000947829. To provide support for creating custom B.11.31 depot-based DVD install
media, the createMediaCatalogs script has been added to Ignite-UX.
QXCR1000949068. The itool interface will now handle the Modify button on Change Depot
Location properly.
QXCR1000960200. The FAQ was updated to include an entry explaining behavior of the
-n option to make_net_recovery.
QXCR1000962110. The FAQ was updated to include an entry documenting issues and
workarounds when using Ignite-UX's graphical interface when system configured to use
advanced name-services for hostname resolution.
QXCR1000968536. Ignite-UX has been enhanced to allow the user to control which LAN
interfaces are managed by DHCP. Prior to this change, Ignite-UX only configured the primary
LAN for DHCP management. A new config file keyword "dhcp_enable[lan]" has been
added as well as changes to the user interface to provide this control.