Ignite-UX release notes HP-UX 11iv1, HP-UX 11iv2 and HP-UX 11iv3 (5900-2307, April 2012)

QXCR1001039432. The -i option of make_sys_image, which was applicable only for
B.11.00 and earlier releases, has been obsoleted.
QXCR1001044588. HP Integrity BL860c i2 Server Blade systems support network boot when
incoming requests are relayed.
QXCR1001045036. Warning messages for B.11.31 clients will be displayed if the selected
path is in either a standby or failed state.
QXCR1001045660. On B.11.31,make_sys_image will not proceed with an archive creation
if legacy device support is disabled on the system. Please enable the legacy device support
using the 'insf -L' command and recreate the archive.
QXCR1001048801. Ignite-UX has improved the logic to search for LIF or archive from a
Recovery tape for an Integrity system, to reduce the time required to restore the system.
* QXCR1001052772. The script called by make_opticaldisc_recovery that looks for
a date specific filename is modified to closely match with the format of the filename instead
of the date itself.
* QXCR1001055810. Ignite-UX has been updated to correctly display the maximum volume
group size in itool window.
QXCR1001057724. When running make_net_recovery with the -r option to resume a
preview, it will now remove all the configuration directories associated with an old recovery
archive.
QXCR1001058334. Recovery image installs of 11.31 clients with either compartments
enabled or configured as Secure Resource Partitions (SRP) are now supported.
QXCR1001059542. Tape archive creation/recovery will succeed on a HP-UX B.11.23
IPF machine even if the /dev/rmt/stape_config file is missing. That file was used to
check the type of the tape which is not required and therefore that check has been removed.
* QXCR1001073659 The save_config script will now correctly process the VxVM volumes
with 5.1 pre-enablement changes in Ignite-UX.
QXCR1001075059. The VxVM components in the Ignite-UX install environment and the
installation depot must be version 5.0 or higher in order to use persistent DSFs.
QXCR1001075174. Support has been added to permit swm-based installs over NFS for
B.11.31.
QXCR1001075974. Ignite-UX will not allow the root volume to be configured under a FlexFC
VFC.
QXCR1001075979. Ignite-UX will not allow swap/dump to be configured under a FlexFC
VFC.
QXCR1001075980. itool now supports NPIV/FlexFC VFC configured on a system.
QXCR1001092353. The fix for QXCR1000942141 has been backed out to support creation
of tape archives on multiple tapes for IPF systems.
QXCR1001093531 Ignite-UX has been modified to detect and support physical memory of
size greater than 2TB(upto 8TB) during the cold installation and Network Recovery.
Notes related to known problems with this release:
There are no new known problems.
Version C.7.12.519 (3/2011) 15