3 Ignite-UX Releases
This section describes supported Ignite-UX releases. Major changes and defect fixes for each
release are described here.
Version C.7.16.283 (3/2013)
The C.7.16.283 release of Ignite-UX supports the following HP-UX release/architecture combinations:
Table 4 HP-UX Release/Architecture Combinations Supported on Ignite-UX Version C.7.16.283
HP Integrity systemsHP 9000 systemsHP-UX release
NoYesB.11.11
YesYesB.11.23
YesYesB.11.31
After downloading from the Web, you can install this version on any server running on any one
of the HP-UX releases listed in the table.
Ignite-UX version C.7.16.283 includes the following new features:
Support for cluster DSF.
Support for boot disk size greater than 2TB (upto 16TB max) during cold installation and
recovery.
This release also includes fixes for the following Change Requests:
QXCR1001056377 Boot disk > 2TB in size can be used now for installing HP-UX 11i v3.
QXCR1001113271 Support for cDSFs into Ignite-UX.
QXCR1001189838 Agile ctl device information is added to io.info and is used for
recovery.
QXCR1001225407 After Ignite-UX recovery, LVM commands will not fail on systems that
have SRP installed .
QXCR1001228658 During Ignite-UX upgrade on the server containing recovery commands
depots,swlist does not complain about the missing INFO file.
QXCR1001235981 Legacy disk instance numbers are mapped correctly.
QXCR1001239595 On HP-UX 11i v2 and later, Ignite-UX now supports the size of Swap,
Dump, and unused logical volumes up to 1TB in size instead of the previous limit of 128GB.
Larger amounts of swap/dump or swap volumes can be utilized in disk or volume groups
created during a cold install or recovery by defining multiple swap/dump or swap volumes.
The limit for unused volumes on 11i v1 is 1TB. However the limit for swap and dump have
not been increased.
QXCR1001245156 Deleting a disk with multiple paths deletes all the paths.
QXCR1001247114 Legacy CD/DVD devices instance numbers are recovered properly.
QXCR1001247383 If pax archive is set in the defaults file, diagnostic messages are
displayed.
Version C.7.15.254 (9/2012)
The C.7.15.254 release of Ignite-UX supports the following HP-UX release/architecture combinations: