Ignite-UX Reference (March 2010, B3921-90005)

ignite(5) ignite(5)
Sufficient disk space to load Ignite-UX and any software depots and/or archives to be used dur-
ing the install.
Access to the Ignite-UX tool set. The tool set may be loaded onto any of the above clients.
Tape/CD-ROM to load Ignite-UX and any software depots planned for distribution on the
server.
Network access to any clients to be installed. Client and server must be on the same subnet if
the initial boot of the client is planned to be over the network.
Ignite-UX Server Setup: Overview
1. Install HP-UX.
2. Install the Ignite-UX software.
3. Set up the core HP-UX software.
4. Add additional applications (optional).
5. Run ignite to complete the configuration and to start the process.
Note: All operations are executed as "privileged user" on the Ignite-UX server. Except where
noted, all commands referenced here are located in /opt/ignite/bin. (See the "privi-
leges" manpage for more information on the privileged user.)
Ignite-UX Server Setup: Details
1. Install HP-UX
Refer to the HP-UX 11i Installation and Update Guide and Read Before Installing or Updat-
ing to HP-UX 11i for the revision of HP-UX 11i that you wish to install or update for instruc-
tions.
2. Install Ignite-UX software.
The Ignite-UX tool-set is contained on the HP-UX application set of CD-ROMs. The soft-
ware bundles are named as follows: Ignite-UX-11-31, Ignite-UX-11-23,
Ignite-UX-11-11, and Ignite-UX-11-00. Each software bundle contains the Ignite-
UX tools in addition to the data files required for support of the particular HP-UX release
indicated by the bundle name. You may load one or more of the Ignite-UX bundles onto your
server depending on which releases of HP-UX you plan on installing onto clients. The entire
set of releases is supported with the IGNITE bundle.
Once the application CD-ROM containing Ignite-UX has been mounted, you may use the
swinstall command to load the desired Ignite-UX bundles. For example, the command
below would load the support needed for installing HP-UX 11.23 onto clients assuming the
CD-ROM is mounted at /cdrom:
swinstall -s /cdrom Ignite-UX-11-23
3. Set up core HP-UX software.
Before Ignite-UX may be used, you must configure the software for it to load onto the clients.
Since both SD sources and archive (non-SD) sources (tar, cpio, or pax) may be used,
both cases will be considered separately below.
For SD operating system software:
For Ignite-UX to use an SD source, you must have a registered SD depot available
and an Ignite-UX configuration file generated from that depot.
If you already have an SD depot containing the core HP-UX software, you may
enable Ignite-UX’s access it by using the make_config and manage_index
commands.
You may also use the Server Setup wizard available from the Welcome screen of the
Ignite-UX server and from the Actions menu. The wizard is self-explanatory.