6.2 HP IBRIX 9000 Storage Network Best Practices Guide (TA768-96069, December 2012)

FSN physical hardware mapping
Table 5 shows the mapping of the logical networks to the server blade and VC interconnect
hardware.
Table 5 9730 IBRIX 9730 unified network physical mapping
Connection Type
VC External
ConnectionVC Module
FSN
Physical
Interface
Allocated
Bandwidth
FSN
InterfaceNetwork
Primary External
Connection
X6Interconnect Bay
1
eth 010 GbBond0User,
Cluster,
Management
LACP trunking with X6X5, X4, X3, X2,
X1
Primary External
Connection
X6Interconnect Bay
2
eth 3
LACP trunking with X6X5, X4, X3, X2,
X1
Physical cabling
Figure 10 IBRIX 9730 unified network minimum cabling
The minimum cabling required to attach an IBRIX 9730 enclosure to a customer network consists
of the four patch cables shown in Figure 10. For maximum redundancy, each patch cable ideally
connects to a physically separate edge switch in the customer network.
Table 6 summarizes the necessary connections.
Unified network 33