6.1.1 HP IBRIX X9000 Network Storage System Release Notes
Documentation changes
ibrixinit command
The syntax for the ibrixinit command is shown incorrectly in the HP IBRIX X9000 Network Storage
System Installation Guide. The correct syntax to install the Fusion Manager, file serving node, and
statstool packages on a file serving node is:
ibrixinit -c clustername -C <CLUSTER_IF> —v <VIF_IP> —m <VIF_NETMASK> —d
<VIF_DEVICE> -w <PORT_NO> -F [-V <USERVIF_IP>] [-D <USERVIF_DEV>] [-n
<USERVIF_NETMASK>]
Installation instructions
New installations
HP IBRIX X9000 software is preinstalled on supported devices. If you need to reinstall the software,
see the administrator guide for your storage system.
Upgrades
The upgrade procedure is provided in the administrator guide for your storage system. Contact HP
Support for assistance with the procedure.
Compatibility/Interoperability
Note the following:
• Every member of the cluster must be running the same version of X9000 software.
• The cluster must include an even number of file serving nodes.
• All X9000 clients must be running 6.0 or later.
Documentation feedback
HP is committed to providing documentation that meets your needs. To help us improve the
documentation, send any errors, suggestions, or comments to Documentation Feedback
(docsfeedback@hp.com). Include the document title and part number, version number, or the URL when
submitting your feedback.
Documentation changes 15