5.6.x HP X9000 Series Network Storage System Installation Guide (TA768-96056, December 2011)
# ibrix_fm -m maintenance
nl
# ibrix_fm –u <management_console_name>
2. Define a new Agile_Cluster_VIF_DEV and the associated Agile_Cluster_VIF_IP.
3. Change the management console's local cluster address from bond0 to bond1 in the X9000
database:
a. Change the previously defined Agile_Cluster_VIF_IP registration address. On the active
management console, specify a new Agile _Cluster_VIF_IP on the bond1 subnet:
ibrix_fm –t –I <new_Agile_Cluster_VIF_IP>
NOTE: The ibrix_fm –t command is not documented, but can be used for this
operation.
b. On each file serving node, edit the /etc/ibrix/iadconf.xml file:
vi /etc/ibrix/iadconf.xml
In the file, enter the new Agile_Cluster_VIF_IP address on the following line:
<property name=”fusionManagerPrimaryAddress”
value=”xxx.xxx.xxx.xxx’/>
4. On the active agile management console, re-register all backup management consoles using
the bond1 Local Cluster IP address for each node:
# ibrix_fm –R <management_console_name> —I <local_cluster_network_IP>
5. Return the backup management consoles to passive mode:
# ibrix_fm –m passive
6. Place the active management console into maintenance mode to force it to fail over. (It can
take up to a minute for a passive management console to take the active role.)
# ibrix_fm –m maintenance
7. Unregister the original active management console from the new active management console:
# ibrix_fm –u <original_active_management_console_name>
8. Re-register that management console with the new values and then move it to passive mode:
# ibrix_fm –R <agileFM_name> —I <local_cluster_network_ip>
nl
# ibrix_fm –m passive
9. Verify that all management consoles are registered properly on the bond1 local cluster network:
# ibrix_fm –f
You should see all registered management consoles and their new local cluster IP addresses.
If an entry is incorrect, unregister that management console and re-register it.
10. Reboot the file serving nodes.
After you have completed the procedure, if the management console is not failing over or the
/usr/local/ibrix/log/Iad.log file reports errors communicating to port 1234 or 9009,
contact HP Support for further assistance.
Completing the installation
For more information, see the following:
• “Post-installation tasks” (page 46)
• “Adding Linux and Windows X9000 clients” (page 49)
40 Installing and configuring X9720 systems