5.5 HP StorageWorks X9720 Network Storage System Administrator Guide (AW549-96026, March 2011)
to flicker green. Note that a disk drive could be in use even if the online/activity LED is not illuminated
green.
IMPORTANT:
Do not remove a disk drive unless the fault/UID LED is amber.
See the HP StorageWorks X9720 Network Storage System Controller User Guide for more information
about the LED descriptions.
X9700cx GSI LED is amber
If the global service indicator (GSI) light on the front panel of the hard drive drawer is lit amber, there
is a problem with one of the enclosure components such as a power supply, fan, or I/O module.
Occasionally, the GSI light goes amber even though the power supply, fan, or I/O module components
are lit green. In this situation, try swapping out each component one at a time, checking the GSI light
after each replacement. See Replacing components in the HP ExDS9100 Storage System for
replacement instructions.
X9700cx drive LEDs are amber after firmware is flashed
If the X9700cx drive LEDs are amber after the firmware is flashed, try power cycling the X9700cx
again. See Upgrading X9700cx I/O module and disk drive firmware for more power cycling
information.
Configuring the Virtual Connect domain
Once configured, the Virtual Connect domain should not need any reconfiguration. However, if the
domain is somehow lost or damaged, this section provides enough information for you to reconstruct
it. The examples in this section use the Virtual Connect CLI.
The system has 3 networks as follows:
->show network * -output=script2
Name;Status;Smart Link;State;Connection Mode;Native VLAN;Private;VLAN Tunnel;Preferred
Speed;Max Speed man_lan;OK;Disabled;Enabled;Failover;Disabled;Disabled;Disabled;1;1
Port;Name;Status;Type;Speed;Role
1;enc0:1:X7;Linked (Active) (1);SFP-RJ45;Auto;Primary
2;enc0:2:X7;Linked (Standby) (1);SFP-RJ45;Auto;Secondary
-------------------------------------------------------------------------------
Name;Status;Smart Link;State;Connection Mode;Native VLAN;Private;VLAN Tunnel;Preferred
Speed;Max Speed ext1;Degraded;Enabled;Enabled;Auto;Disabled;Disabled;Disabled;9;9
Port;Name;Status;Type;Speed
1;enc0:2:X1;Linked (Active) (10);CX4;Auto
2;enc0:2:X2;Not Linked;SFP-RJ45;Auto
3;enc0:2:X3;Not Linked;absent;Auto
4;enc0:2:X4;Not Linked;absent;Auto
5;enc0:2:X5;Not Linked;absent;Auto
6;enc0:2:X6;Not Linked;absent;Auto
-------------------------------------------------------------------------------
Name;Status;Smart Link;State;Connection Mode;Native VLAN;Private;VLAN Tunnel;Preferred
Speed;Max Speed ext2;Degraded;Enabled;Enabled;Auto;Disabled;Disabled;Disabled;9;9
Troubleshooting128