HSG80 Enterprise/Modular Storage RAID Array Fibre Channel Solution Software V8.7A for Windows Release Notes (AA-RH0QL-TE, July 2003)

Host Operating System Notes
53Release Notes – HSG80 Enterprise/Modular Storage RAID Array Fibre Channel Solution
Software Version 8.7A for Windows
which you simply replace an FC HBA in one of your systems. During such a
system or adapter changeover, be sure to manually remap drives to drive letters
using Disk Manager. This restores proper access to your data.
If you replace an FC HBA in a server, you need to reinstall the HBA driver and
then rerun the Fibre Channel Setup utility. This is so that Windows 2000 can
automatically reload the original driver for this adapter and reset many of the
important registry settings. New connections are created on the HSG controller.
Those connections should be renamed and assigned to the appropriate units.
For more information about installing the adapter, see the HSG80 ACS Solution
Software Version 8.7 Installation and Configuration Guide and use the software
on the Solution Software CD-ROM.
Upgrading from Windows NT 4.0 to Windows 2000 or Windows
Server 2003
If you are upgrading from Windows NT 4.0 to Windows 2000 or Windows Server
2003, you must remove the software components installed by the previous version of
the Fibre Channel Setup utility. Follow these steps:
1. Remove the software components installed from the previous Fibre Channel Setup
utility. To do this, locate the previous CD-ROM and run the utility. Follow the
procedures in it to remove components. Alternately, you can use the Add/Remove
Programs applet.
2. Upgrade from Windows NT 4.0 to Windows 2000 or Windows Server 2003 as
instructed by Microsoft's documentation.
3. Reboot.
4. Install the HBA driver upgrade as instructed in the HSG80 ACS Solution Software
Version 8.7 Installation and Configuration Guide.
5. Run the Fibre Channel Setup utility to complete your installation.
ResetTPRLO Parameter in Windows Environments
All Windows SAN installations require the ResetTPRLO (Third Party Logout
Extended Link Service) HBA driver parameter be set to a value of 1. When HBA
driver Version x-4.53a7 or higher is installed, this parameter must be changed from the
default value, which is set to 0.