HSG80 Enterprise/Modular Storage RAID Array Fibre Channel Solution Software V8.7A for Windows Release Notes (AA-RH0QL-TE, July 2003)
Host Operating System Notes
51Release Notes – HSG80 Enterprise/Modular Storage RAID Array Fibre Channel Solution
Software Version 8.7A for Windows
5. For all of the units with access enabled for offline connections, type:
HSGA> SET <unit name> DISABLE_ACCESS=<offline host connection
name #1>
HSGA> SET <unit name> DISABLE_ACCESS=<offline host connection
name #2>
...
6. Delete the offline host connections by typing:
HSGA> DELETE <offline host connection name #1>
HSGA> DELETE <offline host connection name #2>
...
7. Rename the new connections to the name of the previously matching offline host
connection name by typing:
HSGA> RENAME !NEWCONnn <offline host connection name #1>
HSGA> RENAME !NEWCONnn <offline host connection name #2>
...
8. Enable access for these new host connections to the storage units by typing:
HSGA> SET <unit name> ENABLE_ACCESS=<offline host connection
name #1>
HSGA> SET <unit name> ENABLE_ACCESS=<offline host connection
name #2>
...
Windows NT, Windows 2000, and Windows Server 2003
• Windows NT, Windows 2000, and Windows Server 2003 can run MSCS software.
See documents that come with Microsoft's software kits for instructions on setting
up Microsoft clusters.
• There is no Hot Plug support for FC HBAs under Windows NT 4.0, Windows
2000, and Windows Server 2003 at this time. Check the StorageWorks Support
website for updates.
• Windows NT and Windows 2000 support SCSI-2 and SCSI-3 modes. See the
HSG80 ACS Solution Software Version 8.7 Installation and Configuration Guide
that comes with this kit for more information.