HSG80 Enterprise/Modular Storage RAID Array Fibre Channel Solution Software V8.7A for Windows Release Notes (AA-RH0QL-TE, July 2003)

Host Operating System Notes
51Release Notes – HSG80 Enterprise/Modular Storage RAID Array Fibre Channel Solution
Software Version 8.7A for Windows
5. For all of the units with access enabled for offline connections, type:
HSGA> SET <unit name> DISABLE_ACCESS=<offline host connection
name #1>
HSGA> SET <unit name> DISABLE_ACCESS=<offline host connection
name #2>
...
6. Delete the offline host connections by typing:
HSGA> DELETE <offline host connection name #1>
HSGA> DELETE <offline host connection name #2>
...
7. Rename the new connections to the name of the previously matching offline host
connection name by typing:
HSGA> RENAME !NEWCONnn <offline host connection name #1>
HSGA> RENAME !NEWCONnn <offline host connection name #2>
...
8. Enable access for these new host connections to the storage units by typing:
HSGA> SET <unit name> ENABLE_ACCESS=<offline host connection
name #1>
HSGA> SET <unit name> ENABLE_ACCESS=<offline host connection
name #2>
...
Windows NT, Windows 2000, and Windows Server 2003
Windows NT, Windows 2000, and Windows Server 2003 can run MSCS software.
See documents that come with Microsoft's software kits for instructions on setting
up Microsoft clusters.
There is no Hot Plug support for FC HBAs under Windows NT 4.0, Windows
2000, and Windows Server 2003 at this time. Check the StorageWorks Support
website for updates.
Windows NT and Windows 2000 support SCSI-2 and SCSI-3 modes. See the
HSG80 ACS Solution Software Version 8.7 Installation and Configuration Guide
that comes with this kit for more information.