HSG80 Enterprise/Modular Storage RAID Array Fibre Channel Solution Software V8.7A for Windows Release Notes (AA-RH0QL-TE, July 2003)
Host Operating System Notes
Release Notes – HSG80 Enterprise/Modular Storage RAID Array Fibre Channel Solution
Software Version 8.7A for Windows
50
Use the following procedure to upgrade your DS-KGPSA-BC HBA firmware from
Version 2.x to Version 3.x:
1. Connect a PC or terminal to the maintenance port of Controller A and get a listing
of the host connections by typing the command:
HSGA> SHOW CONNECTIONS
The resulting display should appear similar to the following:
Connection Unit
Name Operating system Controller Port Address Status Offset
!NEWCON68 WINNT OTHER 2 021900 OL other 0
HOST_ID=2000-0000-C920-A562 ADAPTER_ID=1000-0000-C920-A562
!NEWCON69 WINNT THIS 1 021900 OL this 0
HOST_ID=2000-0000-C920-A562 ADAPTER_ID=1000-0000-C920-A562
!NEWCON70 WINNT THIS 1 011800 OL this 0
HOST_ID=2000-0000-C921-4D3D ADAPTER_ID=1000-0000-C921-4D3D
!NEWCON71 WINNT OTHER 2 011800 OL other 0
HOST_ID=2000-0000-C921-4D3D ADAPTER_ID=1000-0000-C921-4D3D
W2K01A-A1 WINNT THIS 1 011800 offline 20
HOST_ID=1000-0000-C921-4D3D ADAPTER_ID=1000-0000-C921-4D3D
W2K01A-B2 WINNT OTHER 2 011800 offline 20
HOST_ID=1000-0000-C921-4D3D ADAPTER_ID=1000-0000-C921-4D3D
W2K01B-A2 WINNT THIS 1 offline 20
HOST_ID=1000-0000-C920-A562 ADAPTER_ID=1000-0000-C920-A562
W2K01B-B1 WINNT OTHER 2 offline 20
HOST_ID=1000-0000-C920-A562 ADAPTER_ID=1000-0000-C920-A562
W2K02A-A1 WINNT THIS 1 021800 OL this 40
HOST_ID=1000-0000-C921-4F5E ADAPTER_ID=1000-0000-C921-4F5E
2. Note the WWNs of the ADAPTER_ID of the new connections.
3. Find the offline connections with the same ADAPTER_ID WWNs and note the
unit offsets.
4. Type the following command to get a list of all storage units and the host
connections whose access is enabled:
HSGA> SHOW UNIT FULL