HSG80 Enterprise/Modular Storage RAID Array Fibre Channel Solution Software V8.7A for Windows Release Notes (AA-RH0QL-TE, July 2003)
Operating Constraints
45Release Notes – HSG80 Enterprise/Modular Storage RAID Array Fibre Channel Solution
Software Version 8.7A for Windows
SAN Boot Procedures
Booting from the SAN is supported for Windows NT and Windows 2000. SAN boot
procedures are available on the StorageWorks website.
http://h18000.www1.hp.com/products/storageworks/san/documentation.html
File System Limitations
Table 9 describes known limitations that certain file systems have regarding storage
unit size.
PVA Switch Setting
After installing the EMU in each cabinet, ensure that the SCSI ID number on the PVA
is set according to Table 10 (BA370 enclosures only).
Using FRUTIL to Insert a New Controller
When using FRUTIL to insert a new controller in a dual-redundant controller
configuration, you see a new set of instructions after the new controller was inserted:
Table 9: File System Storage Unit Limitations
Disk
Size
Storageset
Configuration Operating and File System
4 GB Any Windows NT4.0/Windows 2000/Windows
Server 2003 FAT File System
16 TB Any Windows NT 4.0/Windows 2000/Windows
Server 2003 NTFS File System
Table 10: SCSI ID Number on the PVA
Cabinet PVA SCSI ID Setting
Master enclosure 0
First expansion enclosure 2
Second expansion enclosure 3