HSG80 Enterprise/Modular Storage RAID Array Fibre Channel Solution Software V8.7A for Windows Release Notes (AA-RH0QL-TE, July 2003)
ACS Feature Support
37Release Notes – HSG80 Enterprise/Modular Storage RAID Array Fibre Channel Solution
Software Version 8.7A for Windows
NOTE: Repeat step 12 on both controllers (THIS_CONTROLLER and OTHER_CONTROLLER)
until no unwritten data remains in either cache module memory. If unwritten data is present after
several minutes, verify that the WRITEBACK_CACHE switch is disabled on all units by using the
SHOW UNITS FULL command. For any units with the WRITEBACK_CACHE switch enabled,
return to step 11 and proceed.
13. Shut down Controller B by using the following command:
HSGA> SHUTDOWN OTHER_CONTROLLER
NOTE: Disregard any messages pertaining to misconfigured controllers or failover status.
NOTE: After Controller B shuts down, the Reset button 1 and the first three LEDs 2 light up
(see Figure 1). Proceed only after the Reset button stops flashing and remains on.
Figure 1: HSG80 array controller Reset button and LEDs
14. Verify that all units failed over to Controller A by using the following command to
show the status of each unit:
HSGA> SHOW UNITS FULL
The following text is only a portion of the resulting display. An arrow points to the
pertinent status indication:
15. Run VTDPY to verify that all units are online and that there is no I/O activity by
entering the following CLI command:
HSGA> RUN VTDPY
1 Reset button
2 First three LEDs
State:
ONLINE to this controller
Not reserved
NOPREFERRED_PATH
123456
CXO6991A
2
1