HSG80 Enterprise/Modular Storage RAID Array Fibre Channel Solution Software V8.7A for Windows Release Notes (AA-RH0QL-TE, July 2003)

ACS Feature Support
Release Notes – HSG80 Enterprise/Modular Storage RAID Array Fibre Channel Solution
Software Version 8.7A for Windows
36
NOTE: The cache flush timer value is displayed in the caching parameters section. This
parameter is modified during the procedure and must be restored in step 20.
8. For each unit, identify and record the unit write-back cache, read-ahead cache,
read cache, and Preferred Path characteristics by using the following command:
HSGA> SHOW UNITS FULL
These characteristics are modified during the upgrade procedure and must be restored
in step 21.
NOTE: The switch for Preferred Path is available only with a multi-bus configuration. It is not
available in the transparent failover mode.
9. Set the cache flush timer to 1 second by using the following commands:
HSGA> SET THIS_CONTROLLER CACHE_FLUSH_TIMER=1
HSGA> SET OTHER_CONTROLLER CACHE_FLUSH_TIMER=1
10. Clear any unit with the PREFERRED_PATH switch set, by using the following
command as required for each unit:
HSGA> SET <unit-name> NOPREFERRED_PATH
11. Disable write-back, read-ahead, and read caching on all units by using the
following command as required for each unit:
HSGA> SET <unit-name> NOWRITEBACK_CACHE NOREADAHEAD_CACHE
NOREAD_CACHE
NOTE: The xxx_CACHE switches must be entered in the specified order, or the command is
rejected.
12. Determine whether all data was flushed from the cache module by using the
following command on both controllers:
HSGA> SHOW THIS_CONTROLLER
HSGA> SHOW OTHER_CONTROLLER
The following text is only a portion of the resulting display. An arrow points to the
pertinent status indication:
Cache:
256 megabyte write cache, version 0022
Cache is GOOD
No unflushed data in cache
CACHE_FLUSH_TIMER=1 SECOND