HSG80 Enterprise/Modular Storage RAID Array Fibre Channel Solution Software V8.7A for Windows Release Notes (AA-RH0QL-TE, July 2003)
ACS Feature Support
35Release Notes – HSG80 Enterprise/Modular Storage RAID Array Fibre Channel Solution
Software Version 8.7A for Windows
b. Record the status for restoration in step 23.
c. Disable the CCL by using the following command:
HSGA> SET THIS_CONTROLLER NOCOMMAND_CONSOLE_LUN
5. Delete all SNAPSHOT units, if you are upgrading from ACS V8.6S-x to V8.7S-x.
a. Identify all SNAPSHOT units by using the following command:
HSGA> SHOW UNITS FULL
b. Record the configuration for each SNAPSHOT unit for restoration in step 22.
c. Individually delete all SNAPSHOT units by using the following command:
HSGA> DELETE <snapshot-unit-name>
6. Verify that all appropriate units were deleted by using the following command:
HSGA> SHOW UNITS FULL
NOTE: If any other SNAPSHOT units exist, repeat step 5 until they are all deleted.
7. Identify and record the current cache flush timer value by using the following
command:
HSGA> SHOW THIS_CONTROLLER
The following text is only a portion of the resulting display. An arrow points to the
pertinent status indication:
ALLOCATION_CLASS = 1
SCSI_VERSION = SCSI-2
Configured for MULTIBUS_FAILOVER with ZG92810098
In dual-redundant configuration
Device Port SCSI address 7
Time: 14-MAR-2001 15:44:25
Command Console LUN is lun 0 (IDENTIFIER = 0)
Cache:
256 megabyte write cache, version 0022
Cache is GOOD
No unflushed data in cache
CACHE_FLUSH_TIMER=DEFAULT (10 seconds)