HSG80 Enterprise/Modular Storage RAID Array Fibre Channel Solution Software V8.7A for Windows Release Notes (AA-RH0QL-TE, July 2003)
ACS Feature Support
31Release Notes – HSG80 Enterprise/Modular Storage RAID Array Fibre Channel Solution
Software Version 8.7A for Windows
• SWCC
• Large LUN utility (if installed)
NOTE: Do not restart the server at this time if instructed to do so.
5. Insert your Secure Path Software CD and install Secure Path V3.1A for Windows
or Secure Path V4.0-1 or higher for Windows in accordance with the instructions
provided with the product.
6. If you are using Secure Path V3.1A for Windows, apply the Secure Path V3.1A
for Windows SP 3 update.
7. If you are using Secure Path V4.0-1 or higher for Windows, apply the Secure Path
V4.0-1 or higher update.
8. Reboot the server.
9. Insert your Solution Software Kit CD and click Solution Software for Windows.
a. Click Perform Multi Driver Update to install the HBA driver.
b. Click Fibre Channel Software Setup, and then choose one of the multi-bus
Fibre Channel setups, based on your configuration.
c. Click SWCC (optional) to install SWCC components.
NOTE: The latest Large LUN utility must be installed if the storage system is used prior to
upgrading ACS to Version 8.7-1 and a Large LUN configuration was previously employed.
10. Restart the server.
Updating an Existing Cluster
To update an existing cluster by using Secure Path in multi-bus failover mode,
complete the following steps:
1. Log in to the server with an account with administrator privileges.
2. Make note of your original configuration by using Cluster Administrator, and then
move disk resources to the other cluster node. The node being updated should not
have any disk resources online.
3. Set all cluster groups to Prevent failback, by using Cluster Manager, while the
upgrade is taking place.
NOTE: The Cluster Service must continue to run on all nodes. Stopping the Cluster Service
during this procedure could result in a Cluster Service failure and subsequent reinstallation.