HSG80 Enterprise/Modular Storage RAID Array Fibre Channel Solution Software V8.7A for Windows Release Notes (AA-RH0QL-TE, July 2003)
ACS Feature Support
Release Notes – HSG80 Enterprise/Modular Storage RAID Array Fibre Channel Solution
Software Version 8.7A for Windows
30
New Solution Software Kit (V8.7A) Installation Procedures
To install the Solution Software Kit for the first time, complete the following steps:
1. Ensure that the Fibre Channel Adapter (FCA) is not connected.
2. Insert the CD that shipped with the Solution Software Kit and click Solution
Software for Windows.
a. Click Perform Multi Driver Update to install the HBA driver.
b. Click Fibre Channel Software Setup, and then choose one of the multi-bus
Fibre Channel setups, based on your configuration.
c. Click SWCC (optional) to install SWCC components.
NOTE: Do not restart the server at this time if instructed to do so.
3. Using your Secure Path Software CD, install Secure Path V3.1A for Windows or
Secure Path V4.0-1 or higher for Windows in accordance with the instructions
provided with that product. If you are using Secure Path V3.1A, apply the Secure
Path V3.1A for Windows SP 3 update.
4. Shutdown the server.
5. Connect the FCA fibre cables to the switch(es).
6. Restart the server.
Updating the Solution Software Kit with Secure Path on Windows
NT/2000 Server
The following procedures demonstrate how to upgrade your Solution Software Kit, in
conjunction with your Secure Path software, in a multi-bus failover environment.
Updating an Existing Standalone Server
To update an existing standalone server by using Secure Path in multi-bus failover
mode, complete the following steps:
1. Log in to an account with administrator privileges.
2. Stop all applications that access Secure Path storage.
3. Stop the SWCC STEAM agent in Services.
4. Click Add/Remove Program on the Control Panel and uninstall: