HSG80 Enterprise/Modular Storage RAID Array Fibre Channel Solution Software V8.7A for Windows Release Notes (AA-RH0QL-TE, July 2003)
ACS Feature Support
Release Notes – HSG80 Enterprise/Modular Storage RAID Array Fibre Channel Solution
Software Version 8.7A for Windows
28
• Rolling upgrades must occur in succession. For example, you must upgrade from
V8.6 to V8.7-1.
• If you are performing a rolling upgrade, ensure that the variant for the existing
ACS version being upgraded is the same as that of the next version to be
upgraded. For example, if you want to upgrade ACS V8.6P-10, the ACS version
to be upgraded must be the P variant of ACS V8.7-x.
• You must use a dual-redundant configuration to perform rolling upgrades.
• If you are upgrading the P variant of an applicable ACS version, use the
procedures provided in the hp StorageWorks HSG80 Array Controller Version 8.7
Maintenance and Service Guide. This guide provides specific instructions on
upgrading ACS on the initiator and target site.
• You must upgrade the Solution Software Kit before performing the rolling
upgrade procedure in the “Upgrading ACS” section.
CAUTION: HP StorageWorks Secure Path V3.1A for Windows, Service Pack (SP) 3
or Secure Path V4.0-1 or higher for Windows must be used before performing the
rolling upgrade procedure in the “Upgrading ACS” section. If you don’t, data loss may
occur.
Solution Software Kit Upgrade Procedures
Use the procedures in this and the following sections to upgrade your Solution
Software Kit:
1. Perform backups of data prior to upgrade.
2. Verify operating system versions, and upgrade operating systems to supported
versions and patch levels.
3. Upgrade switch firmware.
4. Upgrade the Solution Software Kit.
5. Quiesce all I/O and unmount all file systems for the server being updated before
proceeding.
6. If you are installing an operating system that uses Secure Path, upgrade Secure
Path to the latest version at this time.
7. Upgrade the ACS software.