HSG80 Enterprise/Modular Storage RAID Array Fibre Channel Solution Software V8.7A for Windows Release Notes (AA-RH0QL-TE, July 2003)
New Features
11Release Notes – HSG80 Enterprise/Modular Storage RAID Array Fibre Channel Solution
Software Version 8.7A for Windows
Error Threshold for Drives
CLEAR_ERRORS DRIVE_ERRORS
SET DRIVE_ERROR_THRESHOLD
SHOW DRIVE_ERROR_THRESHOLD
See the HSG80 Array Controller ACS Version 8.7 CLI Reference Guide for complete
syntax details.
FC Switch Support Updates
The following updates and changes to supported FC Switch products are included in
this Solution Software Version 8.7A release:
• Support for the 8/16 Port Fibre Channel Storage Switches (DS-DSGGA-AA
[380591-B21] and DS-DSGGA-AB [380578-B21]) was discontinued because
these switches are limited to four switch, two-hop maximum configurations.
• Firmware for all 1 Gbps SAN Switch products was upgraded to v2.6.0h.
• Added support for the following FC switches, many of which provide 2 Gbps
switch support:
— SAN Switch 2/16 (16 Ports FC, 2 Gbps)
— SAN Switch 2/8-EL (8 Ports FC Entry Level, 2 Gbps)
— SAN Switch 2/16-EL (16 Ports FC Entry Level, 2 Gbps)
— SAN Switch 2/32 (32 Ports FC, 2 Gbps)
— SAN Core Switch 2/64 (32-64 Ports FC, 2 Gbps)
— SAN Director 64 (32-64 Ports FC, 1 Gbps)
— SAN Edge Switch 32 (32 Ports FC, 1 Gbps)
— SAN Edge Switch 16 (16 Ports FC, 1 Gbps)
— SAN Director 2/64 (32-64 Ports FC, 2 Gbps)
— SAN Director 2/140 (140 Ports FC, 2 Gbps)
— SAN Edge Switch 2/32 (32 Ports FC, 2 Gbps)
— SAN Edge Switch 2/16 (16 Ports FC, 2 Gbps)
— SAN Edge Switch 2/24 (24 Ports FC, 2 Gbps)
See "Switch Support", page 21, for part numbers, firmware versions, and additional
information.