HSG80 Array Controller ACS Version 8.2 User Guide (EK-HSG80-UG. B01, July 1998)

B100 HSG80 Users Guide
Caution The IMMEDIATE_SHUTDOWN switch instructs the
controller to immediately shut down, without regard to any data
contained within write-back cache. See Fault-Tolerance for Write-
Back Caching, page 121 for considerations when implementing
write-back cache. Do not perform any hardware changes until the
controller flushes the cache.
Select IMMEDIATE_SHUTDOWN to instruct the controller to run the
self-test program immediately without checking for online devices or
without flushing user data from write-back cache to devices.
Select NOIMMEDIATE_SHUTDOWN to instruct the controller to
flush data from write-back cache before running the self-test program.
Examples
This example shows how to start the self-test program on this
controller:
SELFTEST THIS_CONTROLLER
This example shows how to run the self-test program on the other
controller, even if the other controller cannot flush all data from the
write-back cache:
SELFTEST OTHER_CONTROLLER IGNORE_ERRORS
See also
RESTART controller
SHUTDOWN controller