HSG80 Array Controller ACS Version 8.2 User Guide (EK-HSG80-UG. B01, July 1998)

544 HSG80 Users Guide
Installing DIMMs
Use the following steps to install a DIMM in a cache module:
1. Insert the DIMM straight into the socket and ensure that the notches in
the DIMM align with the tabs in the socket (see Figure 58).
Figure 58 Installing a DIMM
2. Press the DIMM gently until its seated in the socket.
3. Double-check to ensure both ends of the DIMM are firmly seated in the
slot and both retaining clips engage the DIMM.
4. Install the cache module using the steps in either Installing the Cache
Module in a Single Controller Configuration, page 57, or Installing a
Cache Module in a Dual-Redundant Controller Configuration, page
524.
CXO6163A
Retaining
clip
(2x)