HSG80 ACS Solution Software Version 8.7 for Compaq OpenVMS Installation and Configuration Guide
Planning Storage Configurations
2–34 HSG80 ACS Solution Software Version 8.7 for Compaq OpenVMS Installation and
Configuration Guide
To make a storage map, fill out the templates provided in Appendix A as you add
storagesets, partitions, and JBOD disks to the configuration and assign them unit
numbers. Label each disk drive in the map with the higher levels it is associated with,
up to the unit level.
Using LOCATE Command to Find Devices
If you want to complete a storage map at a later time but do not remember where the
disk drives and partitions are located, use the CLI command
LOCATE. The LOCATE
command flashes the (fault) LED on the drives associated with the specific storageset
or unit. To turn off the flashing LEDs, enter the CLI command
LOCATE CANCEL.
The following procedure is an example of the commands to locate all the disk drives
that make up unit D104:
1. Enter the following command:
LOCATE D104
The LEDs on the disk drives that make up unit D104 will flash.
2. Note the position of all the drives contained within D104.
3. Enter the following command to turn off the flashing LEDs:
LOCATE CANCEL
The following procedure is an example command to locate all the drives that make up
RAIDset R1:
1. Enter the following command:
LOCATE R1
2. Note the position of all the drives contained within R1.
3. Enter the following command to turn off the flashing LEDs:
LOCATE CANCEL