HSG80 ACS Solution Software Version 8.7 for Compaq OpenVMS Installation and Configuration Guide
Planning a Subsystem
1–14 HSG80 ACS Solution Software Version 8.7 for Compaq OpenVMS Installation and
Configuration Guide
• Offsets should be divisible by 10 (for consistency and simplicity).
• Unit numbers should be assigned at connection offsets (so that every host
connection has a unit presented at LUN 0).
Table 1–1 summarizes the recommendations for unit assignments based on the
SCSI_VERSION switch.
Assigning Unit Identifiers
When configuring storage units, a unique identifier must be specified for each unit and
this identifier must be unique in the cluster.
This section gives two examples of setting an identifier for a previously created unit:
one using CLI and one using SWCC. The CLI uses the older terms “identifier” and
“unit”, while SWCC uses the terms “LUN ID alias” and “virtual disk”.
Identifier = LUN ID alias
Unit = virtual disk
Using CLI to Specify Identifier for a Unit
The command syntax for setting the identifier for a previously created unit (virtual
disk) follows:
SET UNIT_NUMBER IDENTIFIER=NN
NOTE: For simplicity, StorageWorks recommends that the identifier match the unit number. For
example, to set an identifier of 97 for unit D97, use the following command:
SET D97 IDENTIFIER=97
Table 1–1: Unit Assignments and SCSI_VERSION
SCSI_VERSI
ON
Offset
Unit
Assignment
What the connection sees
LUN 0 as
SCSI-2 Divisible by
10
At offsets Unit whose number
matches offset
SCSI-3 Divisible by
10
Not at offsets CCL