HSG80 ACS Solution Software Version 8.7 for Compaq OpenVMS Installation and Configuration Guide

Using CLI for Configuration
6–6 HSG80 ACS Solution Software Version 8.7 for Compaq OpenVMS Installation and
Configuration Guide
RENAME !NEWCON00 RED1B1
SET RED1B1 OPERATING_SYSTEM=VMS
RENAME !NEWCON01 RED1A1
SET RED1A1 OPERATING_SYSTEM=VMS
SHOW CONNECTIONS
NOTE: Connection table sorts alphabetically.
Mark or tag both ends of Fibre Channel cables.
Plug in the Fibre Channel cable from the second adapter in host “RED.
SHOW CONNECTIONS
Connection
Name
Operating
System
Controll
er
Port Address Status
Unit
Offset
RED1A1 VMS OTHER 1 XXXXX
X
OL other 0
HOST_ID=XXXX-XXXX-XXXX-XXXX ADAPTER_ID=XXXX-XXXX-XXXX-XX
XX
RED1B1 VMS THIS 1 XXXXX
X
OL this 0
HOST_ID=XXXX-XXXX-XXXX-XXXX ADAPTER_ID=XXXX-XXXX-XXXX-XX
XX